| 85M-1602-T Specifications | |
| • Inputs and Outputs | |
| Digital Inputs | 16 channels |
| Isolation | 3k VDC 2k Vrms |
| • Digital Input | |
| Sensor Type | Wet contact (NPN PNP), dry contact |
| I/O Mode | DI, Counter Frequncy |
| Dry Contact | • On: short to GND • Off: open |
| Wet Contact (DI to COM) | • Off: 0 to 3 VDC • On: 10 to 30 VDC |
| Common Type | 8 points per COM |
| Counter Frequency | 5 kHz |
| Digital Filtering Time Interval | Software selectable (by 0.1 ms) |
| • Physical Characteristics | |
| Wiring | I/O cable, 16 AWG (max.) |
| Connector | Spring-type terminal block |
| • Environmental Limits | |
| Operating Temperature | -40 to 75°C (-40 to 176°F) |
| • Power Requirements | |
| Input Current | 363.6 mA @ 3.3 VDC |
| • MTBF (mean time between failures) | |
| Time | 1,132,561 hrs |
| Standard | Telcordia SR332 |
| 85M-2600-T Specifications | |
| • Inputs and Outputs | |
| Digital Outputs | 16 channels |
| Isolation | 3k VDC 2k Vrms |
| • Digital Output | |
| Type | Sink |
| I/O Mode | DO PWM |
| Pulse Output Frequency | 5 kHz |
| Over-Voltage Protection | 45 VDC |
| Over-Current Protection | 2.6 A (4 channels @ 650 mA) |
| Over-Temperature Shutdown | 175°C (typical), 150°C (min.) |
| Current Rating | 200 mA per channel |
| • Physical Characteristics | |
| Wiring | I/O cable, 16 AWG (max.) |
| Connector | Spring-type terminal block |
| • Environmental Limits | |
| Operating Temperature | -40 to 75°C (-40 to 176°F) |
| • Power Requirements | |
| Input Current | 257.6 mA @ 3.3 VDC |
| • MTBF (mean time between failures) | |
| Time | 792,571 hrs |
| Standard | Telcordia SR332 |
| 85M-3800-T Specifications | |
| • Inputs and Outputs | |
| Analog Inputs | 8 channels |
| Isolation | 3k VDC 2k Vrms |
| • Analog Input | |
| Type | Differential |
| Resolution | 16 bits |
| I/O Mode | 4 to 20 mA (wire off) |
| Accuracy | ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C |
| Sampling Rate | • All channels: 100 samples/sec • Per channel: 12.5 samples/sec |
| Input Impedance | 125 ohms (min.) |
| • Physical Characteristics | |
| Wiring | I/O cable, 16 AWG (max.) |
| Connector | Spring-type terminal block |
| • Environmental Limits | |
| Operating Temperature | -40 to 75°C (-40 to 176°F) |
| • Power Requirements | |
| Input Current | 318.2 mA @ 3.3 VDC |
| • MTBF (mean time between failures) | |
| Time | 1,512,906 hrs |
| Standard | Telcordia SR332 |
| 85M-3810-T Specifications | |
| • Inputs and Outputs | |
| Analog Inputs | 8 channels |
| Isolation | 3k VDC 2k Vrms |
| • Analog Inputs | |
| Type | Differential |
| Resolution | 16 bits |
| I/O Mode | 0 to 10 VDC |
| Accuracy | ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C |
| Sampling Rate | • All channels: 100 samples/sec • Per channel: 12.5 samples/sec |
| Input Impedance | 200 kilo-ohms (min.) |
| • Physical Characteristics | |
| Wiring | I/O cable, 16 AWG (max.) |
| Connector | Spring-type terminal block |
| • Environmental Limits | |
| Operating Temperature | -40 to 75°C (-40 to 176°F) |
| • Power Requirements | |
| Input Current | 315.2 mA @ 3.3 VDC |
| • MTBF (mean time between failures) | |
| Time | 1,530,690 hrs |
| Standard | Telcordia SR332 |
| 85M-3801-T Specifications | |
| • Inputs and Outputs | |
| Analog Inputs | 8 channels |
| Isolation | 3k VDC 2k Vrms |
| • Analog Input | |
| Type | Differential |
| Resolution | 16 bits |
| I/O Mode | 4 to 20 mA (wire off) |
| Historical Data Buffering | 60 KB per channel, 6-second data buffer at 5 kHz |
| Accuracy | ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C |
| Sampling Rate | • All channels: 40k samples/sec • Per channel: 5k samples/sec |
| Input Impedance | 125 ohms (min.) |
| • Physical Characteristics | |
| Wiring | I/O cable, 16 AWG (max.) |
| Connector | Spring-type terminal block |
| • Environmental Limits | |
| Operating Temperature | -40 to 75°C (-40 to 176°F) |
| • Power Requirements | |
| Input Current | 378.8 mA @ 3.3 VDC |
| • MTBF (mean time between failures) | |
| Time | 1,426,112 hrs |
| Standard | Telcordia SR332 |
| 85M-3811-T Specifications | |
| • Inputs and Outputs | |
| Analog Inputs | 8 channels |
| Isolation | 3k VDC 2k Vrms |
| • Analog Inputs | |
| Type | Differential |
| Resolution | 16 bits |
| I/O Mode | 0 to 10 VDC |
| Historical Data Buffering | 60 KB per channel, 6-second data buffer at 5 kHz |
| Accuracy | ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C |
| Sampling Rate | • All channels: 40k samples/sec • Per channel: 5k samples/sec |
| Input Impedance | 20 mega-ohms (min.) |
| • Physical Characteristics | |
| Wiring | I/O cable, 16 AWG (max.) |
| Connector | Spring-type terminal block |
| • Environmental Limits | |
| Operating Temperature | -40 to 75°C (-40 to 176°F) |
| • Power Requirements | |
| Input Current | 378.8 mA @ 3.3 VDC |
| • MTBF (mean time between failures) | |
| Time | 1,426,112 hrs |
| Standard | Telcordia SR332 |
| 85M-6600-T Specifications | |
| • Inputs and Outputs | |
| RTD Inputs | 6 channels |
| Isolation | 3k VDC 2k Vrms |
| • RTDs | |
| Input Type | • PT50, PT100, PT200, PT500 (-200 to 850°C) • PT1000 (-200 to 350°C) • JPT100, JPT200, JPT500 (-200 to 640°C) • JPT1000 (-200 to 350°C) • NI100, NI200, NI500 (-60 to 250°C) • NI1000 (-60 to 150°C) • NI120 (-80 to 260°C) • Resistance of 310, 620 |
| Sampling Rate (single channel) | • All channels: 12 samples/sec • Per channel: 2 samples/sec |
| Resolution | 0.1°C 0.1 ohms |
| Accuracy | ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C |
| Input Impedance | 625 kilo-ohms (min.) |
| Wiring | I/O cable, 16 AWG (max.) |
| Connector | Spring-type terminal block |
| • Environmental Limits | |
| Operating Temperature | -40 to 75°C (-40 to 176°F) |
| • Power Requirements | |
| Input Current | 201.5 mA @ 3.3 VDC |
| • MTBF (mean time between failures) | |
| Time | 571,446 hrs |
| Standard | Telcordia SR332 |
| 85M-6810-T Specifications | |
| • Inputs and Outputs | |
| Analog Inputs | 8 channels |
| Isolation | 3k VDC 2k Vrms |
| • Thermocouples | |
| Sensor Type | J (0 to 750°C), K (-200 to 1250°C), T (-200 to 350°C), E (-200 to 900°C), R (-50 to 1600°C), S (-50 to 1760°C), B (600 to 1700°C), N (-200 to 1300°C) |
| Millivolt Type | • Mode: ±78.126 mV, ±39.062 mV, ±19.532 mV • Fault and over-voltage protection: -35 to +35 VDC (power off); -25 to +30 VDC (power on) |
| Sampling Rate (single channel) | • All channels: 12 samples/sec • Per channel: 1.5 samples/sec |
| Resolution | 16 bits |
| Accuracy | ±0.1% FSR @ 25°C ±0.3% FSR @ -40 and 75°C |
| Input Impedance | 1 mega-ohm (min.) |
| Wiring | I/O cable, 16 AWG (max.) |
| Connector | Spring-type terminal block |
| • Environmental Limits | |
| Operating Temperature | -40 to 75°C (-40 to 176°F) |
| • Power Requirements | |
| Input Current | 175.5 mA @ 3.3 VDC |
| • MTBF (mean time between failures) | |
| Time | 2,324,891 hrs |
| Standard | Telcordia SR332 |
| 85M-5401-T Specifications | |
| • Serial Communication | |
| Interface | 4 RS-232/422/485 ports, software selectable (DB44 female) |
| Isolation | 3k VDC 2k Vrms Note: DB44 to 4-port DB9 cable included in the package. |
| • Serial Communication Parameters | |
| Parity | None, Even, Odd |
| Data Bits | 7, 8 |
| Stop Bits | 1, 2 |
| Flow Control | RTS/CTS, XON/XOFF |
| Baudrate | 300 bps to 921.6 kbps |
| • Serial Signals | |
| RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
| RS-422 | Tx+, Tx-, Rx+, Rx-, GND |
| RS-485-4w | Tx+, Tx-, Rx+, Rx-, GND |
| RS-485-2w | Data+, Data-, GND |
| • Physical Characteristics | |
| Connector | DB44 female |
| • Environmental Limits | |
| Operating Temperature | -40 to 75°C (-40 to 176°F) |
| • Power Requirements | |
| Input Current | 375.8 mA @ 3.3 VDC |
| • MTBF (mean time between failures) | |
| Time | 596,611 hrs |
| Standard | Telcordia SR332 |
| Common Specifications | |
| • Power Requirements | |
| Input Voltage | 24 VDC (9 to 48 VDC) |
| • Environmental Limits | |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| Shock | IEC 60068-2-27 |
| Vibration | IEC 60068-2-6 |
| • Standards and Certifications | |
| Safety | UL 508 |
| EMC | EN 55032/24 |
| EMI | FCC Part 15 Subpart B Class A, CISPR 32 |
| EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1000 MHz: 3 V/m 1400 MHz to 2100 MHz: 3 V/m 2100 MHz to 2700 MHz: 1 V/m IEC 61000-4-4 EFT: Power: 1 kV; Signal 0.5 kV IEC 61000-4-5 Surge: Power: 2 kV (L-PE), 1 kV (L-L); |
| Rail Traffic | EN 50155*, EN 50121-3-2, EN 50121-4 *Complies with a portion of EN 50155 specifications. |
| • Warranty | |
| Warranty Period | 5 years |
| Details | See www.moxa.com/warranty |
MOXA, Programmable Controller
ioPAC 8500 Series Expansion Modules
Features and Benefits
- 85M-1602-T: 16 digital inputs, 24 VDC, sink/source type
- 85M-2600-T: 16 digital outputs, 24 VDC, sink-type
- 85M-3800-T: 8 analog inputs, 4 to 20 mA
- 85M-3810-T: 8 analog inputs, 0 to 10 VDC
- 85M-3801-T: 8 analog inputs, 4 to 20 mA, 40 kHz
- 85M-3811-T: 8 analog inputs, 0 to 10 VDC, 40 kHz
- 85M-5401-T: 4 serial ports (RS-232/422/485)
- 85M-6600-T: 6 RTDs