| • Optical-Fiber Side | |
| Fiber Connector | SC or ST |
| Fiber Cable Requirements | ![]() |
| Point-to-Point Transmission | Half-duplex or full-duplex |
| • RS-232/422/485 Side | |
| Connector | DB9 |
| RS-232 Signals | TxD, RxD, GND |
| RS-422 Signals | TxD+, TxD-, RxD+, RxD-, GND |
| RS-485-4w Signals | TxD+, TxD-, RxD+, RxD-, GND |
| RS-485-2w Signals | Data+, Data-, GND |
| Baudrate | 50 bps to 921.6 kbps |
| • Physical Characteristics | |
| Dimensions | 86.8 x 136.5 x 21 mm (3.42 x 5.37 x 0.83 in) |
| Weight | 105 g (0.23 lb) |
| • Environmental Limits | |
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Storage Temperature | -20 to 75°C (-4 to 167°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| • Power Requirements | |
| Input Voltage | 12 VDC |
| Input Current | 12 VDC @ 150 mA |
| • Standards and Certifications | |
| Safety | UL 60950-1 |
| EMC | EN 55032/24 |
| EMI | CISPR 32, FCC Part 15B Class A |
| EMS | EN 61000-4-2 (ESD): Contact: 4 kV; Air: 8 kV EN 61000-4-3 (RS): 80 MHz to 1 GHz: 3 V/m EN 61000-4-4 (EFT): Power: 1 kV; Signal: 0.5 kV EN 61000-4-5 (Surge): Power: 1 kV; Signal: 0.5 kV EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m EN 61000-4-8 (PFMF) EN 61000-4-11 (DIPS) |
| Green Product | RoHS, CRoHS, WEEE |
| Freefall | IEC 60068-2-32 |
| • MTBF (mean time between failures) | |
| Time | 514,926 hrs |
| Standard | Telcordia (Bellcore), GB |
| • Warranty | |
| Warranty Period | 5 years |
| Details | See www.moxa.com/warranty |