- General
- ShellMetal material, IP40
- Net Weight0.245 kg (0.54 lb)
- Gross Weight0.645 kg (1.42 lb)
- Dimensions (W × H × D)145.0 mm × 25.6 mm × 68.45 mm (5.7″ × 1.0″ × 2.69″)
- Operating Temperature0 °C to 40 °C (32 °F to 104 °F)
- Storage Temperature-40 °C to 85 °C (-40 °F to 185 °F)
- Operating Humidity5% to 95% (no condensation)
- Relative Humidity5% to 95% (no condensation)
- Power Supply48 VDC, 1.35 A
- Installation ModeDesk-Mounted,Wall-Mounted
- Max. Power Consumption65 W
- Power Consumption in Idle2 W
- Surge Protection6 KV
- Network Parameters
- Ports4 × 10/100 Mbps PoE port,2 × 10/100 Mbps RJ45 port
- MAC Address Table2 K
- Switching Capacity1.2 Gbps
- Packet Forwarding Rate0.90 Mpps
- Internal Cache768 Kbits
- PoE Power Supply
- PoE StandardIEEE 802.3af,IEEE 802.3at,IEEE 802.3bt
- PoE Power Pin8-pin power: 1/2(-), 3/6(+), 4/5(+), 7/8(-)
- PoE Port
Hi-PoE: Port 1
PoE: Ports 2 to 4
- Max. Port PowerPort 1: 60 W Ports 2 to 4: 30 W
- PoE Power Budget60 W
- Software Function
- Long Range
Ports 1 to 4: up to 300 m.
Long range performance may vary depend on camera model or cable condition.
- VIP PortPorts 1 to 2: data on VIP ports is preferentially forwarded when bandwidth resources are insufficient.
- PoE WatchdogPorts 1 to 4: auto detect and restart the cameras that do not respond.
- HPP
Support one-click activation and remote management via Hik-Partner Pro. Functions supported:
1. Display the port rate.
2. Display the port bandwidth utilization rate.
3. Display the PoE power usage.
4. Display topology information.
5. Display the alarm status.
6. Restart ports and devices.
7. Enable port long-rage mode.
8. Remotely upgrade the device.
- System Maintenance
Support device management via web.
Support DHCP Client. Enabled by default for dynamic assignment of management IP addresses.
Support Super IP, which is a fixed IP address (10.180.190.200) for direct access.
Support management via Hik-Central Pro.
Support remote management via Hik-Partner Pro.
Support cable detection. Abnormal open circuits and short circuits as well as network cable length can be detected.
Supports 802.1ab LLDP for peer device discovery.
Support SNMP v1/v2c for third-party management platform access.
Support port mirroring for fault locating.
- Approval
- EMC
FCC (47 CFR Part 15, Subpart B);
CE-EMC (EN 55032: 2015, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN 50130-4: 2011 +A1: 2014, EN 55035: 2017);
IC (ICES-003: Issue 6);
RCM (ASNZS CISPR 32: 2015)
- Safety
UL (UL 60950-1);
CB (IEC 60950-1:2005, AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition);
CE-LVD (EN 60950-1: 2006 + A11: 2009 +A1: 2010+A12: 2011+A2: 2013, EN 62368-1: 2014+A11: 2017)
- Chemistry
CE-RoHS (201165EU);
WEEE (201219EU);
Reach (Regulation (EC) No.19072006)